The charging station can provide an analog input function, the input analog is AC0-1.0V, which is used to display the current working current.
When the detected working current is greater than the set current value, the charging station will reduce the charging current to the set current value.
Thereby ensuring the safe and reliable operation of the charging station.
EKEPC2-C/S Model 3 EV Charge Controller
Model | EKEPCB2-C/S |
Mode | Mode 3 charging |
Operating Voltage | AC230V±10%,50Hz |
Outputthe PWM Signal | Max:32A,10A/16A/20A/25A/32A adjustable Max:16A,6A/8A/13A/16A Max:63A(customized) |
Basic Function | 2:Overtemperature protection |
Additional Function | 1:RCMU DC6mA leakage monitoring with a axuliary device of RCMU 2:Swape RFID card/NFC start or stop charging function with a axuliary device of RFID module and cards 3:LCD display function with a axiliary device of LCD screen 4:Elecronic lock function with a device Electronic lock 5:DLB function with a axuliary device of CT or kWH meter 6:Overvolatge&Undervoltage protection 7:Over current protection 8:voltage,current,Power for real time monitoring with a axuliary of kWH meter 9:Emergency Stop function with a axuliary device of Pushbutom switch |
Protocol(communication) | -Modbus-RTU protocal and RS485 communication |
Output Auxiliary Voltage | DC12V/100mA\DC5V/100mA |
Ambient Temperature | -40℃-+50℃ |
Humidity | <=85% |
IP Degree | IP22 |
Colling Method | Natural cooling |
Installation Method | Din-Rail mounted |
The charging station with a LCD to display which can show the working status and charging related data , it is convenient and intuitive.