EKEC5 basic type internal is a EVSE EV charging PCB board
Advantages:
1)Nice and samll appearance design and can be customized with different shell colors
2)With overload protection, over voltage protection, under voltage protection, short, circuit protection, over temperature protection, emergency stop and other functions
3)Can add a RFID module and cards,using card start/stop charging,card number can customized,also can add new by customer themself(No billing card)
4)Can working with a DLB current monitoring device for a DLB function,the device can using CT
EV Charging Modes | Mode 3 charging |
Rated Voltage | AC 240V ±10% |
Rated Current | Max 32A |
Power | Max:7.3KW |
Rated frequency | 50Hz |
Over voltage category (OVC) | OVC III |
Insulation resistance | R > 1 MΩ; |
AC withstand voltage | 1430V |
Impulse dielectric withstand voltage (1,2 μs/50 μs) (Uimp) | 4kV |
Protection against electric shock | Class I |
Electrical life (contactcor) | 100,000 |
Electrical life (Interface) | 100,000 |
Standby Power Consumption | <8W |
Ocpp1.6J Protocal | Suppport Ethernet/Wifi Communication |
Type of EV connection | Case C(Cable Version) |
universal interface | T1:SAE J1772,T2:IEC/EN 62196-2,GB/T:20234.2-2015 |
Pollution degree | PD 3 |
IP protection class . | IP54 |
Altitude during operation (m) | <2000m |
Altitude of test laboratory | <50m |
Work Humidity | 3%~95% |
Operation temperature: | -25℃— 40℃ |
Colling | Natural Air Cooling |
Mounting method | mounted on walls, poles or equivalent positions |
Normal environmental conditions | indoor use;Outdoor use |
Product Dimension (mm) | 357*245*123 |
Installation Dimension (mm) | 180*280 |
The AC charger require external MCB for overload protection and short-circuit protection to be installed in upstream distribution box |
●: Defult Green: Simple Choice Blue: Multiple Choice |
Selection Code | ||
Model | EKEC5 | ||
Net Mode | Ocpp1.6J Protocal | Suppport Ethernet/Wifi/4G/3G/2G Communication using EKEPCB2 Controller |
● |
Case C | Cable type (Case C) Defaut value is 5M,other length can customized | ● | |
Socket & Plug Standard | American standard Type 1(T1): SAE J1772 | T1 | |
Europe Standard Type 2(T2)T2: IEC/EN 62196-2 | T2 | ||
China Standard: GB/T20234.2-2015 | GBT | ||
Power | 3.6KW,AC230V±10% 50Hz,16A,1P+N+PE | 3 | |
7.3KW,AC230V±10% 50Hz,32A,1P+N+PE | 7 | ||
Protection | Configuration Device | ||
Overtemperature Protection | Chip Overtemperature Protection | ● | |
Residual Current protection | RCMU | IEC62955 standard AC30mA+DC6mA Residual current protection (Should at least installation a Type A RCD in front of Charger) |
● |
PEN falut protection | Relay | Using for UK TNS System for PEN loss protection | 0 |
RFID | RFID module with card | Support swape RFID card stop and start charging | 1 |
DLB | Current Transformer | CT Connected in Main circuit only for single phase | 3 |
kWH meter (out Station) | kWH meter Connected in Main circuit both for single phase or three phase, other brand meter using pls checking the Charger usage manual |
4 | |
Emergency Stop | Emergency stop switch | ● | |
Box Color | Silver color box | S | |
Green color box | G | ||
Red color box | R |
Note: Model Selection Example: EKEC5-T2-7-1-S