EKEC4 is a ecmonic design wallbox, internal components we choosing module din-rail product,
such as module design EV charge controller and module contactor,
RFID and DLB functions can be configured according to customer demand,
the products comply with IEC61851-1 standard.
Advantages:
1) Small size wall box,IP 65 IP degree
2) Insise module device are more easy maintain and repair, it using module contactor instead of relay
will have a good electric life and electric clearrance promise, anti-gigh and low temperature
3)Different power 3.5KW/7.3KW/11KW/22KW are same charger housing
4)Can working with a DLB current monitoring device for a DLB function,the device can using
CT for single phase or a RS485 communication kWH meter for both single phase or theree phase
5)Inside controller with Modbus-RTU protocal and RS485
EV charging modes | Mode 3 charging |
Rated voltage | AC 240V ±10%, AC 420V ±10% |
Rated current | Max 16A, Max 32A |
Rated frequency | 50Hz |
Over voltage category (OVC) | OVC III |
Insulation resistance | R > 1 MΩ |
AC withstand voltage | 1430V |
Impulse dielectric withstand voltage (1,2 μs/50 μs) (Uimp) | 4kV |
Protection against electric shock | Class I |
Electrical life (contactcor) | 100,000 |
Electrical life (Interface) | 100,000 |
Standby Power Consumption | <8W |
Type of EV connection | Case B (Socket version) / Case C (Cable Version) |
universal interface | T1: SAE J1772, T2: IEC/EN 62196-2, GB/T: 20234.2-2015 |
Pollution degree | PD 3 |
IP protection class | IP54 |
Altitude during operation (m) | <2000m |
Altitude of test laboratory | <50m |
Work Humidity | 3%~95% |
Operation temperature | -25℃— 40℃ |
Colling | Natural Air Cooling |
Mounting method | mounted on walls, poles or equivalent positions: |
Normal environmental conditions | indoor use; Outdoor use |
Product Dimension (mm) | 357*245*123 |
Installation Dimension (mm) | 180*280 |
The AC charger require external MCB for overload protection and short-circuit protection to be installed in upstream distribution box |
●: Defult Green: Simple Choice Blue: Multiple Choice |
Selection Code | ||
Model | EKEC4 | ||
Case B/C | Socket type (Case B) | S | |
Cable type (Case C) Defaut value is 5M,other length can customized | C | ||
Socket & Plug Standard | American standard Type 1(T1):SAE J1772 | T1 | |
Europe Standard Type 2(T2)T2:IEC/EN 62196-2 | T2 | ||
China Standard :GB/T20234.2-2015 | GBT | ||
Power | 3.6KW,AC230V±10% 50Hz,16A,1P+N+PE | 3 | |
7.3KW,AC230V±10% 50Hz,32A,1P+N+PE | 7 | ||
11KW,AC400V±10% 50Hz,16A,3P+N+PE | 11 | ||
22KW,AC400V±10% 50Hz,32A,3P+N+PE | 22 | ||
Protection | Configuration Device | ||
Overtemperature Protection | Chip Overtemperature Protection | ● | |
Residual Current protection | RCMU | IEC62955 standard AC30mA+DC6mA Residual current protection (Should at least installation a Type A RCD in front of Charger) |
● |
PEN falut protection | Relay | Using for UK TNS System for PEN loss protection | 0 |
RFID | RFID module with card | Support swape RFID card stop and start charging | 1 |
Electronic Lock | Electronic Lock | Support lock the plug when charging | 2 |
DLB | Current Transformer | CT Connected in Main circuit only for single phase | 3 |
kWH meter (out Station) | kWH meter Connected in Main circuit both for single phase or three phase, other brand meter using pls checking the Charger usage manual |
4 | |
OV&UV protection, Over current protection, voltage, current, Power for real time monitoring |
KwH meter (in station) | a kWM meter with MID certificate | 6 |
Surge Protective | SPD | Only for single phase | 7 |
Emergency Stop | Emergency stop switch | 8 |
Note: Model Selection Example: EKEC4-S-T2-22-12